Specifications
For a pdf file of specifications for products, click here
RegistRead for Electric Metering
Output Type: Form A, digital, dry contact
Resolution: 10 outputs per revolution of dial, typically 1 kwh/pulse
Max. Pulse Rate: Based on meter speed, typically > 1 minute
Duty Cycle: 60% on, 40% off, ± 6%
Temperature: Operational from -40° to +240°F
Moisture: Operational to 100% humidity:
Case is plated to protect from corrosion; all electronics are potted.
Length: 1.12″ Width: .75″ Height: .30″ Weight: .6oz
Maximum switching voltage D.C.: 200 volts
Maximum switching current D.C.: 0.5 amps
Maximum switching watts D.C.: 10 watts
Minimum voltage breakdown D.C.: 220 volts
Contact resistance: 0.2 ohms
Open circuit resistance: > 100,000,000 ohms
Operation Time: 0.6ms